Zanussi ZGG659ICX Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
7
OVERALL DIMENSIONS
Width: 580 mm
Depth: 510 mm
Height: 88 mm
Weight: 12,5 Kg
Instructions for the Installer
CUT OUT DIMENSIONS
Width: 550 mm
Depth: 470 mm
Thickness: 30 mm
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand
corner
Electric:
230-V 50Hz supply, 3 core flexible cable with
non rewireable plug.
Appliance Gas supply: LPG 30 mbar
Appliance Class: 3
Appliance category: I 3
Engineers technical data
Burner Nominal Power
LPG (Butane "A")
Diameter Feeding
Tap. By-Pass Pressure
kW kCal/h Nozzle gh mbar (*)
Auxiliary (dia. 42 mm.) 0,95 814 50 75 28
Semi-rapid (dia. 57 mm.) 1,60 1368 066 126 35 30
Rapid (dia. 90 mm.) 2,45 2095 77 193 45
(*) 1 mbar = 10 mm. water coloumn.
Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local
Service Centre.
SYMPTOM
# There is no spark when lighting the gas
# The gas ring burns unevenly
SOLUTION
$ Check that the unit is plugged in and the
electrical supply is switched on
$ Check that the RCCB has not tripped (if
fitted)
$ Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
$ Check the main jet is not blocked and the
burner crown is clear of food particles.
$ Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.