Zanussi ZGX66424XA Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
AB
C
D
E
A) Green and Yellow
B) 3 amp fuse
C) Brown
D) Cord clamp
E) Blue
The wires in the cord are coloured as follows:
Green and yellow - Earth
Blue - Neutral
Brown - Live
Replacement of the connection cable
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the let-
ter 'E', or the earth symbol
, or coloured
green and yellow.
2. Connect the blue (neutral) wire to the ter-
minal which is marked with the letter 'N' or
coloured blue.
3. Connect the brown (live) wire to the termi-
nal which is marked with the letter 'L'. It
must always be connected to the network
phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to the
voltage load and the working temperature. The
yellow/green earth wire (B) must be approxi-
mately 2 cm longer than the live and neutral wire
(A).
AB
Warning! A cut off plug inserted into a 13
amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is disposed
of safely.
Important! The replacement of electric cable
must be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the current
regulations.
Building In
min. 55 mm
min. 650 mm
560 mm
min. 100 mm
30 mm
480 mm
min. 600 mm
10 mm
11 mm
11 mm
A
3 mm
12
www.zanussi.com
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare