If after some tries the burner does not
light, check if the crown and its cap are in
correct positions.
C
B
A
A) Burner cap and crown
B) Thermocouple
C) Ignition candle
C
D
B
A
A) Burner cap
B) Burner crown
C) Ignition candle
D) Thermocouple
Warning! Do not keep the control knob
pushed for more than 15 seconds.
If the burner does not light after 15 seconds,
release the control knob, turn it into off position
and try to light the burner again after minimum
1 minute.
Important! In the absence of electricity you
can ignite the burner without electrical device;
in this case approach the burner with a flame,
push the relevant knob down and turn it
counter-clockwise to maximum gas release
position.
If the burner accidentally goes out, turn the
control knob to the off position and try to
light the burner again after minimum 1 minute.
The spark generator can start automatical-
ly when you switch on the mains, after in-
stallation or a power cut. It is normal.
Turning the burner off
To put the flame out, turn the knob to the sym-
bol
.
Warning! Always turn the flame down or
switch it off before you remove the pans
from the burner.
Helpful hints and tips