Cleaning of the spark plug
This feature is obtained through a ceramic ignition candle
with a metal electrode. Keep these components well clean
to prevent difficult lighting and check that the burner
crown holes are not obstructed.
Periodic maintenance
Periodically speak your local Service Force Centre to
check the conditions of the gas supply pipe and the pres-
sure adjuster, if fitted.
What to do if…
Problem Possible cause Remedy
There is no spark when lighting the
gas
• There is no electrical supply • Make sure that the unit is connec-
ted and the electrical supply is
switched on.
• Control the fuse. If the fuse is re-
leased more than one time, refer
to a qualified electrician.
• Burner cap and crown are placed
uneven
• Make sure that the burner cap and
crown are in correct positions.
The flame is blow out immediately af-
ter ignition
• Thermocouple is not heated suffi-
cient
• After lightning the flame, keep the
knob pushed for approximately 5
seconds.
The gas ring burns unevenly • Burner crown is blocked with food
residues
• Make sure that the injector is not
blocked and the burner crown is
clear of food particles.