Zanussi ZCG053GW1 Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
18
The use of gas cooking appliance results in the
production of heat and moisture in the room in
which it is installed. Ensure that the kitchen is
well ventilated; keep natural ventilation holes
open or install a mechanical ventilation device
(mechanical extract hood).
Prolonged intensive use of the appliance
may call for additional ventilation, for
example opening of a window, for example
increasing the level of mechanical
ventilation where present.
Gas connection must be carried out
according to the rules in force.
Conversion of gas
Your cooker is designed to work with natural
gas, and is convertible for use with propane or
butane.
For changing the gas type it is necessary
to:
replace the nozzles (hob and oven);
adjust the minimum level (hob and
oven);
adjust the air regulation (oven);
check the gas connection;
Tableau nr.1
Tableau des injecteurs
Cat.: II
2H 3B/P
Burner
Normal
power
(kW)
Economic
power
(kW)
Gas Type
Pressure
(mbar)
By-pass
(mm)
Air
regulation
(mm)
Nozzle
diameter
(mm)
Cons
g/h
2,60 0,75 Natural Gas G20 20 - 1,13 -
2,70 0,72 Butan G30 50 - 0,75 196,33
Rapide
2,40 0,63 Propan G31 50
0,38
- 0,75 171,39
1,90 0,45 Natural Gas G20 20 - 0,96 -
2,00 0,43 Butan G30 50 - 0,60 145,43
Semirapide
1,70 0,40 Propan G31 50
0,28
- 0,60 121,40
1,00 0,35 Natural Gas G20 20 - 0,70 -
1,00 0,35 Butan G30 50 - 0,43 72,71
Auxiliary
0,85 0,31 Propan G31 50
0,26
- 0,43 60,70
2,60 1,00 Natural Gas G20 20 2,5 1,15 -
2,60 1,00 Butan G30 50 2,5 0,70 189,05
Oven
2,30 0,85 Propan G31 50
0,42
2,0 0,70 164,25
Seitenansicht 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 47 48

Kommentare zu diesen Handbüchern

Keine Kommentare