ADAPTATION TO DIFFERENT TYPES OF GAS
SUBSTITUTION OF THE
NOZZLES
Remove the grills:
Remove the caps and baffles from the burners:
With a tubular spanner no. 7 unscrew and remove
(fig. 5) the nozzles substituting them with those
corresponding to the type of gas used (see tab):
Remount the parts carrying out the operations
described in reverse. Then substitute the caliber
plate (positioned near the gas supply connection)
with the one corresponding to the new type of
gas. This can be found in the injector bag
supplied.
If the pressure of gas used is different (or
variable) from that foreseen an appropriate
pressure regulator should be installed on the entry
tube.
In case pressure regulators for GPL are used these
should conform to the regulations in force.
REGULATION OF THE
MINIMUM
To regulate the minimum bring the tap to the
minimum flame position.
Extract the knob.
If the tap is of a type with the pin by-pass inside
the bar (Fig. 6-8), it is sufficient to screw or
unscrew according to the type of gas as indicated
in the following paragraph.
If the tap is of a type with a lateral by-pass (Fig.
8) it is necessary to detach the command panel by
applying pressure to the lateral projection (Fig. 7),
then insert a screwdriver through the hole until
the pin is reached.
When transforming from methane gas to GPL gas
fully screw down the by-pass pin.
Finally check that by quickly turning the tap from
the maximum position to the minimum position
the burner is not extinguished; remount the parts
carrying out the operations described in reverse.
The above-described adaption operations can be
easily carried out whatever the positioning or
fixture of the hob to the kitchen unit.
Fig. 6
FO 0254
TAP
Burner Ø By-pass
of tap
1/100 mm
Auxiliary 28
Semi-rapid 35
Rapid 45
c) valvular tap
a) minimum
regulation
screw
b) normal tap
Fig. 8
Fig. 9
Fig. 5
Fig. 7
MAINTENANCE
It is recommended the appliance be checked at
least every 2 years to ansure the appliance keeps
operating at his best.
If a problem is encountered with the appliance at
any time, contact your nearest service agent or
this company for advice.
Periodically check thecondition and efficiency of
the gas pipe and the pressure regulator; in case of
malfunctioning do not attempt to repair, but
substitute the damaged part.
To guarantee good functioning and maximum
safety the gas regulation taps should be
periodically greased.
The periodic lubrification of the taps must
be carried out by qualified personnel who
should also be contacted in case
irregularities are encountered in the
functioning of the apparatus.
FO 1045
TYPE TYPE NOZZLE NOMINAL
NOMINAL
OF GAS OF BURNER MARKS GAS
PRESSURE
1/100 mm CONSUMPTION kPa
MJ/h
Rapid (large) 135 10.0
Semi-rapid (medium) 100 5.4 1,0
Auxiliary (small) 72 3.0
Rapid (large) 86 10.0
Semi-rapid (medium) 71 6.5 2,75
Auxiliary (small) 50 3.2
NATURAL
GAS
(methane)
L.P.G.