Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the by-pass screw
position.
1
1
The by-pass screw
– If you change from natural gas 20 mbar to liquid
gas, fully tighten the adjustment screw in.
– If you change from liquid gas to natural gas 20
mbar, undo the by-pass screw approximately 1/4
of a turn.
Warning! Make sure the flame does not go out when
you quickly turn the knob from the maximum
position to the minimum position.
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on
the rating plate agree with the voltage and the power of
the local power supply.
• This appliance is supplied with a mains cable and
plug.
• Any electrical component must be installed or replaced
by the Service Force Centre technician or qualified
service personnel.
• Always use a correctly installed shockproof socket.
• Make sure that there is an access to the mains plug af-
ter installation.
• Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
• The appliance must not be connected with an extension
cable, an adapter or a multiple connection (risk of fire).
Check that the ground connection is in conformity with
the standard and regulations force.
• The power cable must be placed in such a way that it
does not touch any hot part.
• Connect the appliance to the mains with a device that
lets to disconnect the appliance from the mains at all
poles with a contact opening width of minimum 3 mm,
eg. automatic line protecting cut-out, earth leakage
trips or fuse.
• None of a parts of the connection cable can not get a
temperature 90°C. The blue neutral cable must be con-
nected to the terminal block label with "N". The brown
(or black) phase cable (fitted in the terminal block con-
tact marked with "L") must always be connected to the
live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
or equivalent type. Make sure that the cable section is ap-
plicable to the voltage and the working temperature. The
yellow/green earth wire must be approximately 2 cm lon-
ger than the brown (or black) phase wire.