Seitenansicht 16
Burner Ø By-pass in 1/100
mm
Rapid 42
Gas burners
Burner Normal
power
Reduced
power
Type of gas Pressure Injector di-
ameter
Usage
kW kW mbar mm g/h
Auxiliary
burner
1,00 0,35 Natural Gas G20 20 0,70 -
1,00 0,35 Butane G30 28 - 30 0,50 72,71
0,85 0,31 Propane G31 28 - 30 0,50 60,70
Semi-rapid
burner
2,00 0,43 Natural Gas G20 20 0,96 -
2,00 0,43 Butane G30 28 - 30 0,71 145,43
1,70 0,38 Propane G31 28 - 30 0,71 121,40
Rapid burn-
er
3,00 0,72 Natural Gas G20 20 1,19 -
3,00 0,72 Butane G30 28 - 30 0,88 218,14
2,60 0,63 Propane G31 28 - 30 0,88 185,68
Gas Connection
Choose fixed connections or use a flexible pipe
in stainless steel in compliance with the regula-
tion in force. If you use flexible metallic pipes,
be careful they do not come in touch with mo-
bile parts or they are not squeezed.
Flexible nonmetal pipes connection
If it is possible to easily and fully control the gas
connection, you can use a flexible pipe. You
must tightly attach the flexible pipe by clamps.
To install, use a pipe holder. Make sure that you
tightly attach the pipe holder to the gasket, and
then continue with the gas connection. The
flexible pipe is correct when:
It cannot become hotter than room tempera-
ture or higher than 30 °C.
It is no longer than 1500 mm.
It does not compress.
It is not subject to traction or torsion.
It does not make contact with sharp edges or
corners.
You can easily examine it in order to check
its condition.
To preserve the flexible pipe, you must regularly
check if:
It does not show cracks, cuts or burn marks
on the two ends and its length.
The material is correctly elastic and not hard-
ened.
The fastening clamps are not rusted.
It is not expired.
If you can see one or more defects, do not re-
pair the pipe, but replace it.
Important! After installation is complete, use a
soapy solution and never a flame to see if you
sealed all the pipe fittings perfectly.
The gas supply ramp is on the rear side of the
control panel.
Warning! Before gas connection
disconnect the mains plug from the
mains socket or switch off the fuse in the
fuse box. Close the primary valve of the
gas supply.