Power Management
The cooking zones of the cooking surface have
a maximum power.
The maximum power is reached when the heat
setting 9 has been set for all cooking zones.
Two cooking zones generate a pair (see figure)
and therefore, the power management shares
the maximum available power between these
cooking zones.
When the power function is selected for one
cooking zone, the power management makes
the additional power for this cooking zone avail-
able by reducing the power of the correspond-
ing other cooking zone.
Example: the heat setting 9 is selected on one
cooking zone. The power function is switched
on for the corresponding cooking zone. The
power function is carried out but the heat set-
ting 9 of one of the cooking zones and the pow-
er function for the other cooking zone of the pair
exceed the maximum power for both at the
same time. For this purpose, the power man-
agement reduces the power of the cooking
zone that switched on first from 9 to example
5 and the display of this cooking zone changes
between 9 and 5 and then stays at the current
possible maximum 5. (If the display changes
between 9 and 5 or 9 and 3 or another value
depends on the type of appliance and the size
of the cooking zone.).