INSTALLATION
WARNING! Refer to Safety chapters.
LOCATION OF THE APPLIANCE
You can install your freestanding appliance with
cabinets on one or two sides and in the corner.
Keep a distance of about 1 cm
between the appliance and the back
wall to make sure that the lid opens.
For minimal distances for fitting check the table.
Minimum distances
Dimension mm
A 400
B 650
C 150
TECHNICAL DATA
Voltage 220 - 240 V
Frequency 50 - 60 Hz
Appliance class 1
Dimension mm
Height 850 - 870
Width 600
Depth 600
OTHER TECHNICAL DATA
Appliance category: II2H3B/P
LPG: G30 (3B/P) 28-30 mbar
Natural Gas: G20 (2H) 20 mbar
BYPASS DIAMETERS
BURNER Ø BYPASS 1/100 mm
Auxiliary 29 / 30
Semi-rapid 32
Triple Crown 67
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW REDUCED POWER kW
INJECTOR MARK
1/100 mm
Triple Crown 4.0 1.80 146
22