To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to the
voltage load and the working temperature. The
yellow/green earth wire (B) must be approxi-
mately 2 cm longer than the live and neutral
wire (A).
AB
Warning! A cut off plug inserted into a
13 amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is
disposed of safely.
Important! The replacement of electric cable
must be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the current
regulations.
Building in
40-50 mm
55 mm
30 mm
min. 650 mm
490 mm
min. 100 mm
270 mm
If several 30 cm hobs are to be installed side
by side into the same cut out, an assembly kit
including a support side bracket and supple-
mentary seals is available at our Service Cen-
tres. The relevant installation instructions are
supplied within the kit package.
R 5mm
min.
55mm
270
+1
mm
490
+1
mm
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be
easy to remove and let an easy access in case
a technical assistance intervention is necessa-
ry.