Electrical connection
The unit is preset to work with a voltage of single
phase 230 V.
Before making the connection make sure that:
- the energy power available in the user's house is
sufficient for the normal supply of this appliance
(see rating plate).
- the unit is correctly connected to earth through a
suitable plug and according to the installation
country Laws.
- the socket or the omnipolar switch used for the
connection must be easilv reached with the in-
stalled appliance.
The appliance is supplied with electric cable,
therefore you will have to fit it with a standard plug,
suitable for the total electric load shown on the rating
plate. The plug is to be inserted into a suitable wall
socket.
If you wish to directly connect to the mains, you
have to interpose an omnipolar switch with a
minimum opening between contacts of 3 mm, be-
tween the unit and the mains, complying with the
existing regulations.
The brown live wire (originating from the clamp
of the appliance junction box) must always be
connected to the phase of the mains supply. In any
case, the supply cord must be positioned in such a
way as it does not reach in any point a temperature
higher by 50°C than the room temperature.
mbar, undo the by-pass screw about 1/4 of a
turn, until a small regular flame is obtained.
Reassemble the parts following the same
procedure backwards.
Finally, check the flame does not go out when
quickly turning the knob from the maximum position to
the minimum position.
Replacement of the electric cable
The replacement of electric cable must
be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the
current regulations.
Should the supply cord need to be replaced, use
only the following cable types: H07 RN-F, H05 RN-
F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90), H05 BB-
F. It is necessary that the yellow/green earth wire is
about 2 cm longer than the live and neutral ones (see
diagram).
The section of the cable should be 3x1,5 mm
2
minimum.
After the connection, test the heating elements
for about 3 minutes to ensure that they are working
correctly.
The manufacturer refuses any responsability
in cases where normal safety measures are not
observed.
Ground (yellow - green)
Neutral
wire
Phase